Innovation in fire proof paint

Products:

Product Description

A two component, air drying Aluminium paint, specially designed to protect the materials from fire.

Features

  • The Paint prevents Metal, Wood, Plastic, Cloth & other similar materials from fire
  • Coated surfaces do not catch fire or burn
  • Coated surfaces prevent flame spreading
  • Excellent Weathering properties
  • Excellent Water, Acid & Alkali resistance
  • Air drying coating
  • Does not require any special techniques for application

Recommended for

  •  Petroleum storage tanks, Plants, Depots, Vehicles, Petrol Pumps etc.
  •  Defence explosive storage, Godowns, Ware houses etc
  •  Oil refineries, Pipelines etc.
  •  Oil drilling platforms & machineries
  •  Electric Cable Wires
  •  Fire fighting equipments, Clothes
  •  PVC pipes for electric wires
  •  Aeroplanes, Helicopters,
  •  Ships
  •  Railways
  •  Other public transport vehicles like Buses
  •  Kitchens, Hotels, Homes, Cinema halls, Multiplexes,Shopping malls, High rise buildings
  • Plastic parts of Cars, Scooters, Bike, Air conditioners  etc
  • Building materials like Plywood, Partical boards, Wood,  Pre-fabricated doors, Panels etc
  • Cars, Bikes etc.
  • Server room, Record room, Electric & Electronic distribution rooms

Technical Data 

Colour   
:
Metallic Aluminium
Coverage  
:
15 to 20 m2 per Litre
Coating Thickness
:
30 +  5 microns DFT per coat
Method of Application
:
 Brush, Air Spray, Airless Spray, Dipping, Flow Coating, Curtain coating, Tumbling, Roller Coating etc.

Film Properties

 Drying Time ( air  dry )
:
Touch  Dry    60 minutes
Hard Dry       24  hours
Over coating interval with self 
:
24 Hours
Finish 
:
Glossy and smooth
Water Resistance 
:
Excellent
Acid Resistance ( 3% HCl ) 
:
Excellent
Alkali Resistance ( 3% NaOH ) 
:
Excellent
Solvent Resistance 
:
Excellent
Adhesion ( by cross hatch method )
:
100%
Flexibility
:
Passes O T bend test
Scratch Hardness
:
1000  gms.
Impact Resistance
:
more than 60 Kg cm.
Weather Resistance
:
more than 6 years
Salt Spray Test (100 hours)
:
Passes the test
U/V resistance  
:
Excellent

Application Procedure and Other Details

Mixing : The paint is supplied in two separate containers Pack (A) and Pack (B).
Shake well both the containers before use.
Mix the components in proper ratio by uniform Stirring.
Once the components are mixed ,it must be used within working pot life period.
Mixing Ratio   : 1 :  1 by Volume
Working Pot Life ( at various temp.) :  2 Hours ( below 25 0C ), 1.5 Hours ( upto 40 0C )
1  Hour   ( above 40 0C )
Method of Application : The paint can be applied by any method e.g. brush, Air spray, Airless Spray, Dipping Flow coating, Curtain coating, Tumbling, Roller coating etc.
Film Thickness  : The wet film thickness ( WFT ) should not be less than 50 microns.
Thinner     : Use  G-Tech Thinner for thinning the paint. Do not thin more than required.

 

Passes following standards

(1)  BS  476-Part 5-1979
Test for ignitibility (Fire test on building materials)

(2)  ANSI/IEEE Standard 383-1974
Test for Class IE Electric Cables, Field Splices and connections for Nuclear Power Generating Stations

 (3)  BS- 476- Part 7
Test for Surface spread of flame

 (4)  IS 12777 : 1989
Test for flame spread of product

 (5)  NFPA 255
Test for fire retardant coating

 (6)  ASTM- E84:98
Test for fire retardant coating

 (7)  UL 723
Test for fire retardant coating


Surface Preparation

  • All surfaces to be coated must be perfectly cleaned.  The presence of oil grease,  dust,  rust, etc. on the surface will not give satisfactory result.
  • Oil grease should be removed by either wipe out method or solvent/emulsion  degreasing method
  • Rust, scales and other deposites on the metal surface should be cleaned by abrasive blast cleaning method or by using wire brushes or abrasion tools.
  • Plastics & Rubber surfaces should be cleaned by solvent wipe out method to remove oils & greases and other lubricating materials deposited on them.
  • Wood should be properly seasoned with minimum moisture content.  There should not be any type of coating on the surface.
  • DO NOT APPLY ANY TYPE OF PRIMER OR SEALER ON THE SURFACE
  • The paint should be applied directly on the surface.  It can be recoated any number of times to increase the film thickness.
  • The hard dry time (Air dry) of the paint is 24 hours but it can be dried hard within one hour by stoving at 120 0C.


Comparision Chart

Design By Shruti Infotech